The concentration of NaOH in the bath is continuously detected by measuring the weight of the liquid using high sensitive pressure sensor. The required volume of fresh NaOH is measured and dosed continuously in to the bath to keep the concentration constantly at preset value which is prescribed in the finishing program file.B
Functions | |
mngMeasuring and controlling of NaOH concentration | |
Selection of control program by finishing program file | |
Display and memory of the measuring and controlling data | |
Self diagnosis function | |
Features | |
Concentration is measured by flow type high sensitive sensor with self calibration method using water and high sensitive and maintenance free. | |
Guarantee of stabilized mercerizing finish and accurate concentration control | |
Automated control of process by registering finishing program | |
Dimensions/Weight | |
400W~447D~1750H | |
Approx100Kg |