Uneven distribution of chemical liquid in the bath
Why
- Insufficient mixing of the liquid / single feeding inlet of the liquid
- Location of the outlet and the inlet of the liquid circulation pipe is too close.
- Fabrics which pass through the liquid in high speed give a little effect to the mixing of the liquid.
Problem
- Finishing fault on one side of the fabric / occurrence of pin holes
Solution
- Improvement of the liquid mixing in the bath
Water contamination at the re-start after holiday
Why
- Deterioration of the water feeding pipe
- sedimentation in the pipe during the stopping of the operation
Problem
- Contamination of the concentration controller inner part
Solution
- To equip an enforceable water draining device in the concentration controller to purge off the water at the start of operation
Freezing inside the pipe at the location of low temperature area
Why
- Prevention measures against freezing for the auxiliary piping is not taken care, although the same for the main piping is done
Problem
- It gives damages to the pump at the start when the pipe is clogged by freeze
Solution
Handling error when the controller stops by accident
Why
- The controller stops suddenly due to power failure while the controller is still under the operation cycle
Problem
- he equipment can be contaminated by the chemical liquid which is left inside the equipment until it is restarted and the equipment may become in trouble
Solution
- Use proper procedure to stop the equipment