ANAC Corporation

SEEDA-CE

Menu

-CONCENTRATION MEASURING & CONTROLLING PART-
SEEDA-CE Control method CPU control
Measuring method Measuring method
Measuring range Free Nitric Acid 0- 20%
Cerium(IV) 0-30%
Measuring Accuracy Nitric Acid Less than +/-0.2% of measured value
Cerium(IV) Less than +/-0.2% of measured value
Number of production line which the equipment can control Up to 3 lines
Data display Color LCD (concentration)j
Cabinet dimensions 450W~425D~1400H
Weight Appro~100Kg
-CHEMICAL LIQUID METERING & FEEDING PART-
SEEDA-CE Pump control system Inverter control
Metering pump type Diaphragm type
Metering pump material PTFE resin
Metering range 0-300ml/min
Sample liquid circulation pump Magnet type
Circulation pump material Circulation pump material
Number of metering pump Q
Number of metering pump P
Outer dimension 800W~600D~1600H
Weight Approx. 100Kg
-REAGENT STORAGE PART-
SEEDA-CE Pump control system Inverter control
Articles in storage Reagents for measuring
Outer dimensions 670W~350D~800H
Weight Approx.50Kg

Please, inquire us if your measuring range does exceed the above mentioned range.